FT_HEADMODEL_LOCALSPHERES
Note that this reference documentation is identical to the help that is displayed in MATLAB when you type “help ft_headmodel_localspheres”.
FT_HEADMODEL_LOCALSPHERES constructs a MEG volume conduction model in with a local sphere fitted to the head or brain surface for each separate channel This implements Huang MX, Mosher JC, Leahy RM. "A sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG." Phys Med Biol. 1999 Feb;44(2):423-40 Use as headmodel = ft_headmodel_localspheres(mesh, grad, ...) Optional arguments should be specified in key-value pairs and can include radius = number, radius of sphere within which headshape points will be included for the fitting algorithm maxradius = number, if for a given sensor the fitted radius exceeds this value, the radius and origin will be replaced with the single sphere fit baseline = number feedback = boolean, true or false See also FT_PREPARE_HEADMODEL, FT_PREPARE_VOL_SENS, FT_COMPUTE_LEADFIELD