 +=====  FT_QUALITYCHECK =====
 +
 +Note that this reference documentation is identical to the help that is displayed in MATLAB when you type "help ft_qualitycheck"​.
 +
 +<​html><​pre>​
 +  <a href=/​reference/​ft_qualitycheck><​font color=green>​FT_QUALITYCHECK</​font></​a>​ performs a quality inspection of a given MEG/EEG dataset,
 +  stores (.mat), and visualizes the result (.png and .pdf).
 + 
 +  This function segments the data into 10-second pieces and performs the
 +  following analyses:
 +   1) reads the properties of the dataset
 +   2) computes the headpositions and distance covered from recording onset (CTF only)
 +   3) computes the mean, max, min, and range of the signal amplitude
 +   4) detects trigger events
 +   5) detects jump artifacts
 +   6) computes the powerspectrum
 +   7) estimates the low-frequency (&lt;2 Hz) and line noise (~50 Hz)
 + 
 +  Use as
 +    [info, timelock, freq, summary, headpos] = ft_qualitycheck(cfg)
 +  where info contains the dataset properties, timelock the timelocked data,
 +  freq the powerspectra,​ summary the mean descriptives,​ and headpos the
 +  headpositions throughout the recording
 + 
 +  The configuration should contain:
 +    cfg.dataset = a string (e.g. '​dataset.ds'​)
 + 
 +  The following parameters can be used:
 +    cfg.analyze ​  = string, '​yes'​ or '​no'​ to analyze the dataset (default = '​yes'​)
 +    cfg.savemat ​  = string, '​yes'​ or '​no'​ to save the analysis (default = '​yes'​)
 +    cfg.matfile ​  = string, filename (e.g. '​previousoutput.mat'​),​ preferably in combination
 +                     with analyze = '​no'​
 +    cfg.visualize = string, '​yes'​ or '​no'​ to visualize the analysis (default = '​yes'​)
 +    cfg.saveplot ​ = string, '​yes'​ or '​no'​ to save the visualization (default = '​yes'​)
 +    cfg.linefreq ​ = scalar, frequency of power line (default = 50)
 +    cfg.plotunit ​ = scalar, the length of time to be plotted in one panel (default = 3600)
 + 
 +  See also <a href=/​reference/​ft_preprocessing><​font color=green>​FT_PREPROCESSING</​font></​a>,​ <a href=/​reference/​ft_read_header><​font color=green>​FT_READ_HEADER</​font></​a>,​ <a href=/​reference/​ft_read_data><​font color=green>​FT_READ_DATA</​font></​a>,​ <a href=/​reference/​ft_read_event><​font color=green>​FT_READ_EVENT</​font></​a>​
 +</​pre></​html>​