FT_REALTIME_BRAINAMPPROXY
Note that this reference documentation is identical to the help that is displayed in MATLAB when you type “help ft_realtime_brainampproxy”.
FT_REALTIME_BRAINAMPPROXY reads continuous data from a BrainAmp EEG acquisition system through the RDA network interface and writes it to a FieldTrip buffer. The FieldTrip buffer is a network transparent server that allows the acquisition client to stream data to it. An analysis client can connect to read the data upon request. Multiple clients can connect simultaneously, each analyzing a specific aspect of the data concurrently. Use as ft_realtime_brainampproxy(cfg) The configuration should contain cfg.host = string, name of computer running the recorder software (default = 'eeg002') cfg.port = number, TCP port to connect to (default = 51244) cfg.channel = cell-array, see FT_CHANNELSELECTION (default = 'all') cfg.feedback = 'yes' or 'no' (default = 'no') The target to write the data to is configured as cfg.target.datafile = string, target destination for the data (default = 'buffer://localhost:1972') cfg.target.dataformat = string, default is determined automatic cfg.target.eventfile = string, target destination for the events (default = 'buffer://localhost:1972') cfg.target.eventformat = string, default is determined automatic To stop this realtime function, you have to press Ctrl-C See also FT_REALTIME_SIGNALPROXY, FT_REALTIME_SIGNALVIEWER